Cosmo COS-UMC30 Instrukcja i Przewodnik Użytkownika Strona 3

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 2
28"/33"
1"
4
"
28"/33"
6"
3"
9"
4"
6"
CENTER LINE
HOOD
MOUNTING
SCREWS
(in cabinet bottom)
CABINET FRONT
3
DUCTED INSTALLATION
Determine whether the hood will discharge vertically or
horizontally. For vertical or horizontal discharge, run ductwork
between the hood location and roof cap or wall cap.
A minimum 6” round duct must be used to maintain maximum
airow efciency.
Always use rigid type metal ducts only.
Whenever possible reduce the number of transitions and turns
in the ductwork. If a long duct run is required increase the duct
size from 6” to 7”.
If elbows or bends are required; install as far away from the
hood as possible.
Minimum mounting height between the range and the bottom
of the hood should be no less than 26”.
Maximum mounting height between the range and the bottom
of the hood should be no more than 34”
WARNING!
FIRE HAZARD
NEVER implement ductwork in a space between walls, crawl
spaces, attics or garages. All exhaust must be vented outside.
Use metal ductwork only. Fasten all connections with sheet
metal screws and certied silver tape or duct tape.
2. Use the following diagram for placement of ductwork and
electrical cutout in cabinet. For a non-ducted installation, DO
NOT cut a duct access hole.
DUCTED INSTALLATION (CONT)
The hood is designed for installation under a kitchen
cabinet:
WARNING
To reduce the risk of electrical shock, switch the power off at
the service panel. Lock or tag the service panel to prevent
power from being switched on.accidentally.
1. Remove the baffle lters from the unit.
2. Reinforce cabinet with 1” x 2” wood strips if additional
support is required.
26”~34” ABOVE
COOKING SURFACE